Wire strike protection system
<templatestyles src="Module:Message box/ambox.css"></templatestyles>
This article needs additional citations for verification. (October 2010) |

The wire strike protection system (WSPS) is a mechanical wire cutter designed to mitigate the risk of wire strikes whilst flying helicopters at low-level.
History
<templatestyles src="Multiple image/styles.css" wrapper=".tmulti"></templatestyles>
During the six-year period covering calendar years 1974 through 1979, wire strike accidents accounted for a significant share of United States Army Aviation peacetime mishaps, accounting for 8% of aircraft damage, 6% of aircraft-related injuries, and 16% of aircraft-related fatalities.[1]: 9 Over a similar period covering the ten years between 1970 and 1979, 208 civil helicopters were involved in wire strike accidents. Of these, 88 were destroyed (42%) and 37 (11%) of the 331 people involved were killed.[2]: 5, 7 The most common cause of civil helicopter aerial accidents between 1975 and 1977 was striking wires and poles.[2]: 1
Bristol Aerospace developed a WSPS qualified for the Bell OH-58 Kiowa under contract to the Canadian Armed Forces in May 1979.[1]: 9 Nelson Chan is credited with inventing WSPS, according to the patents granted in 1980.[3][4] Bristol staged a series of 52 tests of the WSPS by mounting it on the fuselage of a wrecked Kiowa; the fuselage was loaded onto a flatbed truck and driven into wires at speeds ranging from 15 to 60 mph (13 to 52 kn; 24 to 97 km/h), yaw angles ranging from 0 to 45°, and a variety of cables that were typically used in overhead power and telecommunication transmission lines, including a <templatestyles src="Fraction/styles.css"></templatestyles>3⁄8 in (9.5 mm) 7-strand steel cable with a tensile strength exceeding 10,000 lb (4,500 kg).[1]: 9–10
Because the Bristol testing did not determine the effectiveness of the lower fuselage-mounted cutter, and was a ground-based test that did not evaluate how a wire strike with the cutter would affect aircraft attitude during flight, the United States Army Research Laboratory conducted supplemental pendulum swing tests at the Impact Dynamics Research Facility located at Langley Research Center with a Kiowa in October 1979.[1]: 11 An additional deflector to protect the skids, landing gear, and tail boom (including the rotor and vertical stabilizer) was also tested, but was found to be ineffective.[1]: 11, 15–19, 41
During the Langley tests, an OH-58 was attached to the end of a 196-foot (60 m) long cable, pulled back, and released to swing through wires mounted horizontally at a height of approximately 22 feet (6.7 m).[1]: 14 Similar pendulum tests were subsequently performed at Langley for Bell UH-1H[5] and AH-1S helicopters in 1981 and 1982.[6]
All small to medium [lower-alpha 1] United States Army helicopters were fitted with WSPS in a retrofit programme that was completed in 1992.[7] Between 1996 and 2002 the US Army had no fatal wire strike accidents.[7] In civil helicopter operations, wire cutters were thought to be most effective for agricultural flights.[2]: 37–38 Of the 208 wire strike accidents in the 1970s, almost half could have been avoided with wire cutters and other recommended mechanical upgrades.[2]: 45
Description

The system is typically mounted around the front of American military helicopters,[6] rescue helicopters and of civilian helicopters involved in agricultural work. It is effective when the helicopter strikes the wires at angle of less than 90 degrees and at speeds more than 30 knots (35 mph; 56 km/h).[7] The system is designed to cut a <templatestyles src="Fraction/styles.css"></templatestyles>3⁄8-inch (9.5 mm) steel cable with a breaking strength of 12,000 lb (5,400 kg).[7]
The WSPS developed by Bristol, which is typical of most cable cutters today, consists of a roof-mounted cutter, a lower cutter fitted to the fuselage,[lower-alpha 2] and a deflector fitted to the middle of the windshield to guide the cable into the cutters.[1]: 9 [7] Sometimes a windshield wiper protector frame is used to stop the cables from catching on wiper motor shafts.[8][unreliable source?] As installed, the OH-58 WSPS developed by Bristol weighs 16.3 lb (7.4 kg) and requires 40 man-hours to install.[1]: 15
Wire Strike Protection System is a registered trademark of Magellan Aerospace, the parent company of Bristol via acquisition.[9] Dart Aerospace markets an equivalent apparatus under the name Cable Cutter System.[10] Cable cutting systems to protect helicopters have been developed by other manufacturers, including MD Helicopters (1981),[11] Custom Air (1987),[12] Airbus Helicopters (2008[13] and 2011),[14] and Bell Helicopter (2014).[15] Another invention aims to protect the rotor by equipping the control rods with cutting edges.[16]
See also
Notes
References
External links
- www.helicopterpage.com - WSPS (How Helicopters Work) [unreliable source?]
- Wire Strike Accidents in General Aviation: Data Analysis 1994 to 2004 – Page 33
- Wire Strike Protection System, MDHS 500 Maintenance Manual
- Magellan Aerospace Announces New Bell Helicopter Wire Strike Protection System Development
- Template:Youtube. Marketing video from Magellan/Bristol that includes development of WSPS. Clips from flatbed and pendulum testing are shown.
- Template:Youtube. Video of a helicopter wire strike that occurred during a rescue exercise. The helicopter was equipped with a WSPS.
- Prior art
- <templatestyles src="Citation/styles.css"/>DK patent 38811C, Jacob Christian Hansen-Ellehammer, "Flyvemaskine", published Lua error: bad argument #1 to "get" (not a valid title)., assigned to Fabrikant af Motorer og Motorkøretøjer
- <templatestyles src="Citation/styles.css"/>DE Grant 739409C, Georg Baierle & Gustav Leutner, "An einem Flugzeug angebrachte Vorrichtung zum Zerstoeren von Sperrdraehten", published Lua error: bad argument #1 to "get" (not a valid title).
- <templatestyles src="Citation/styles.css"/>US Grant 2335952A, James Martin, "Cable cutting device for use on aircraft", published Lua error: bad argument #1 to "get" (not a valid title).
- <templatestyles src="Citation/styles.css"/>AU Grant 6573374A, William Ronald Smith & Sydney Langford Howlett, "Improvements in and relating to cable specification or other line cutting devices", published Lua error: bad argument #1 to "get" (not a valid title)., assigned to Commonwealth of Australia
- ↑ 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 Lua error: bad argument #1 to "get" (not a valid title).
- ↑ 2.0 2.1 2.2 2.3 Lua error: bad argument #1 to "get" (not a valid title).
- ↑ <templatestyles src="Citation/styles.css"/>CA patent 1079182, Nelson Chan, "Cable-cutting device", published Lua error: bad argument #1 to "get" (not a valid title)., assigned to Canada Minister of National Defence
- ↑ <templatestyles src="Citation/styles.css"/>US patent 4215833, Nelson Chan, "Cable-cutting device", published Lua error: bad argument #1 to "get" (not a valid title)., assigned to Canada Minister of National Defence
- ↑ 5.0 5.1 Lua error: bad argument #1 to "get" (not a valid title).
- ↑ 6.0 6.1 6.2 Lua error: bad argument #1 to "get" (not a valid title).
- ↑ 7.0 7.1 7.2 7.3 7.4 Lua error: bad argument #1 to "get" (not a valid title).
- ↑ WSPS
- ↑ Wire Strike Protection System™. Retrieved 2 April 2020 from Magellan Aerospace
- ↑ Cable Cutters. Retrieved 2 April 2020 from DART Aerospace
- ↑ <templatestyles src="Citation/styles.css"/>US patent 4407467, Charles F. Emigh & Morris Goldin, "Tactical wire-cutter system for helicopters", published Lua error: bad argument #1 to "get" (not a valid title)., assigned to McDonnell Douglas Helicopter Co
- ↑ <templatestyles src="Citation/styles.css"/>US patent 4826103, James M. McKown, "Active cable-cutting assembly for aircraft", published Lua error: bad argument #1 to "get" (not a valid title)., assigned to Custom Air Inc.
- ↑ <templatestyles src="Citation/styles.css"/>FR patent 2935956, Gerald Claeys, "Dispositif sectionneur de cables", published Lua error: bad argument #1 to "get" (not a valid title)., assigned to Airbus Helicopters SAS
- ↑ <templatestyles src="Citation/styles.css"/>FR patent 2982844, Marc Denante & Lacroix Pierre Prudhomme, "Dispositif sectionneur de cables, et aeronef", published Lua error: bad argument #1 to "get" (not a valid title)., assigned to Airbus Helicopters SAS
- ↑ <templatestyles src="Citation/styles.css"/>US patennt 9725165, Michael Smith; Chen-Ho Tho & Anand Kumar Marimuthu, "Cable cutter system", published Lua error: bad argument #1 to "get" (not a valid title)., assigned to Bell Helicopter Textron Inc.
- ↑ <templatestyles src="Citation/styles.css"/>US patent 5286170, William W. Brannon, "Helicopter wire strike cutter", published Lua error: bad argument #1 to "get" (not a valid title).
Cite error: <ref>
tags exist for a group named "lower-alpha", but no corresponding <references group="lower-alpha"/>
tag was found
- Pages with script errors
- Articles with short description
- Articles needing additional references from October 2010
- Articles with invalid date parameter in template
- All articles needing additional references
- All articles lacking reliable references
- Articles lacking reliable references from December 2018
- Aircraft components
- Aviation safety
- Helicopter equipment
- Wire
- Pages with reference errors